The question I get asked in houses in multiple occupation is not whether emergency lighting is a good idea. It is whether this particular house needs it, and the honest answer is that the fire risk assessment decides. A two-storey shared house with a short, straight stair often does not. A converted Victorian with a long ground-floor corridor, a stair that turns, an internal lobby and no windows on the escape route often does, and so does anything a council licence names it for.
The legal footing is the Regulatory Reform (Fire Safety) Order 2005, which makes the responsible person assess the risk and keep escape routes usable, including when the lights go out. Local authority HMO licence conditions can then add specifics. The technical benchmark is BS 5266-1, the code of practice for emergency lighting, with BS EN 1838 setting the light levels and BS EN 50172 (BS 5266-8) covering testing. The fire risk assessment cost guide covers who does the assessment and what it picks up, and the HMO licence cost guide explains where licence conditions come in.
This is a features overview of seven products, not a design. Emergency lighting has to light the actual route, at the actual spacing, from the actual door to the actual street, and that is a layout question for an assessor or a competent designer. Bear in mind too that several cheap listings are 110V site-lighting units, which are no use in a UK house. I have left those out and every product below is a 230V mains fitting.
The one I’d buy
LightHub LED IP65 3hr emergency bulkhead with exit legends
For most shared houses, a bulkhead that can be wired either way, rated IP65 and carrying a three-hour battery is the sensible default, and this listing offers that with exit legends included. You choose maintained or non-maintained when it is wired, so one product code covers a landing, a stair foot and a back door. Look for the certification marking on the live listing, and have an electrician wire it.
Typically £15–£35
Check price on AmazonHow I judge emergency lighting
Maintained or non-maintained? A non-maintained light is off until the supply fails. A maintained one is on all the time, as a normal light or a lit sign. In a shared house with a lit hall, non-maintained is normal. Maintained matters where people who do not know the building use it, which is more a licensed premises than a four-bed let.
How long does the battery last? The usual rating is three hours, and councils commonly ask for it where people sleep. A one-hour fitting is cheaper and sometimes acceptable, but only if your assessor says so in writing.
Is it built to the standard? A genuine fitting is designed to BS EN 60598-2-22 and the listing should say so. A listing that just says “emergency bulkhead” tells you the battery exists and nothing about whether it will light the floor.
Can it test itself? The standard asks for a brief functional test monthly and a full-duration test each year, recorded in a log. Self-testing units do this automatically and show a fault on a small LED. They cost more and save a surprising amount of effort.
Where does it go? IP65 for outside doors, cellars and damp porches. IP20 is fine inside a dry hall. Slimline suits a narrow stair. The weather rating is the thing people forget until a unit fills with condensation.
The comparison
| Product | Type | Key feature | Typical price | Best for | |
|---|---|---|---|---|---|
| LightHub LED IP65 3hr emergency bulkhead with exit legends | Bulkhead, maintained or non-maintained | IP65, 3 hour, exit legends | ~£15–£35 | Most HMO landings and stairs | View |
| Knightsbridge IP65 6W LED emergency bulkhead, non-maintained | Bulkhead, non-maintained | 6W, IP65, non-maintained | ~£15–£40 | Plain emergency-only cover | View |
| Sight ECO emergency LED bulkhead with exit sign | Bulkhead with exit sign, IP65 | Exit sign, 24m viewing, up to 3 hours | ~£20–£45 | External doors and wet areas | View |
| AuctionzLtd slimline LED emergency bulkhead | Slimline bulkhead, maintained or non-maintained | Slimline, waterproof, 3 hour battery | ~£12–£30 | Budget fit-out of several units | View |
| LEDBRITE LED emergency exit sign, 4W, self-testing | Exit sign, self-testing | 4W, IP20, self-test, LiFePO4, 29m | ~£35–£65 | Landlords who want the testing handled | View |
| LightHub surface emergency exit sign with arrow legends | Surface exit sign | Arrow legends, 3 hour, 25m | ~£15–£35 | Marking the way to the door | View |
| Bright Source 4-in-1 emergency LED exit sign | Exit sign, four mounting options | 5W, IP20, 3 hour, 4 mounting options | ~£15–£35 | Awkward ceilings and walls | View |
The picks in detail
LightHub LED IP65 3hr emergency bulkhead with exit legends
Best overall
The listing describes an LED bulkhead that can be wired as maintained or non-maintained, rated IP65, with a three-hour emergency duration and exit legends supplied. That is the useful combination: one fitting that covers a landing, a stair or a rear exit, and a legend kit so the same unit can double as a sign over a door. It is the type of fitting a fire risk assessor expects to see in a converted house. The detail to check on the live listing is the certification marking and the stated standard before you rely on it.
For
- Maintained or non-maintained from one fitting, chosen at wiring
- Three-hour duration, the figure councils usually ask for in sleeping accommodation
- Exit legends included, so it can mark a route as well as light it
Against
- Bulkhead styling is utilitarian, which some freeholders dislike in period hallways
- Needs a permanent live feed, so an electrician should wire it
Typically £15–£35
Check price on AmazonKnightsbridge IP65 6W LED emergency bulkhead, non-maintained
Best non-maintained
Knightsbridge is a long-established UK electrical accessories brand, and this is a plain 230V, 6W, IP65 non-maintained bulkhead: dark in normal use, lit on battery when the supply fails. Non-maintained is the usual choice for a landing or hallway that already has its own light, because the tenant never has a second fitting glowing at night. It does one job and does not pretend otherwise. If your assessor wants the escape route lit at all times, this is the wrong type.
For
- Off in normal use, so no light spill into bedrooms
- Known UK brand with a straightforward listing
- IP65 copes with damp porches, cellars and outbuildings
Against
- Non-maintained only, so it cannot be converted to maintained
- Marks no exit by itself without a separate sign
Typically £15–£40
Check price on AmazonSight ECO emergency LED bulkhead with exit sign
Best for outside doors
This one is described as an IP65 weatherproof bulkhead with an emergency exit sign built in, maintained or non-maintained, with a stated viewing distance of 24m and up to three hours of emergency light. The outside of the final exit is the bit people forget: the escape route has to be lit all the way to a place of safety, and a rear door onto a dark yard is exactly where a failed supply hurts. A weatherproof fitting with its own legend is a tidy answer.
For
- Weatherproof, so it suits the final exit and covered porches
- Built-in exit sign saves a separate fitting
- Stated viewing distance gives you something to check against the layout
Against
- “Up to” three hours is worth confirming against the listing
- A busier, larger body than a plain bulkhead
Typically £20–£45
Check price on AmazonAuctionzLtd slimline LED emergency bulkhead
Budget pick
A slimline waterproof bulkhead, listed as maintained or non-maintained with a three-hour battery and a legend kit. The slimmer body is the reason to pick it where a deep fitting would catch a head or sit awkwardly on a narrow stair. It is the cheaper end of the market, so buy one and look at it before you order a dozen: check the finish, the legends and what the listing says about the standard.
For
- Slim profile suits narrow stairs and tight landings
- Dual mode and three-hour battery at a low price
- Legends included
Against
- Budget range, so build quality is worth inspecting before a bulk order
- Seller-branded rather than a major lighting manufacturer
Typically £12–£30
Check price on AmazonLEDBRITE LED emergency exit sign, 4W, self-testing
Premium pick
The distinguishing feature here is the automatic self-test. The listing describes a 4W exit sign with a LiFePO4 battery, maintained or non-maintained, stated as viewable from 29 metres. Most of the cost of emergency lighting over its life is testing, because the standard asks for a short monthly check and a full-duration test each year. A self-testing unit does the routine itself and flags a fault with an indicator, which is useful for a landlord with several houses and no wish to stand under every light with a key. You still keep a log, and you still check the indicators.
For
- Automatic self-test reduces the monthly and annual chore
- LiFePO4 battery chemistry, stated on the listing
- Longest stated viewing distance in this guide
Against
- Costs more than the manual bulkheads
- IP20 means indoor, dry locations only
Typically £35–£65
Check price on AmazonLightHub surface emergency exit sign with arrow legends
Best exit sign
A surface-mounted exit box with up, left and right arrow legends, a three-hour battery and a stated 25m viewing distance. An exit sign and an emergency light are different jobs. The light shows you the floor; the sign tells you which way to go, and in a house with a turn in the corridor or a door that does not look like the way out, that matters. The arrow legends are what make one box usable above a door, at the foot of a stair or at a change of direction.
For
- Three arrow directions from a single box
- Maintained or non-maintained operation per the listing
- Surface mounting, so no chasing into the wall
Against
- Marks the route but gives little floor lighting by itself
- Check the legends are the green running-man pictogram you want
Typically £15–£35
Check price on AmazonBright Source 4-in-1 emergency LED exit sign
Most flexible mounting
The headline is four mounting options, with an up-direction tile included, 5W, IP20 and a three-hour rechargeable battery per the listing. That flexibility is worth having where the ideal position is a sloping soffit, a low beam or a lobby with no flat wall above the door. In an older building the position of the fixing is often the whole difficulty.
For
- Four mounting methods solve awkward positions
- Up-direction tile supplied
- Three-hour recharging battery
Against
- Indoor use only at IP20
- Fewer details published about self-test or certification than the premium pick
Typically £15–£35
Check price on AmazonWhat actually matters — and what doesn’t
Position matters more than the fitting. The aim is that someone who has lost the lights can find the way to a place of safety. That means light over each exit, at changes of direction and level, at stairs, and outside the final exit. Seven well-chosen units in the right places beat twenty bought in a bundle.
Wiring matters. A fitting needs a permanent live supply so the battery keeps charging, taken from the lighting circuit it serves, so that when that circuit fails the light comes on. It is not a plug-in job. Ask the electrician to cover it alongside your periodic inspection; the EICR cost guide explains what that involves.
Testing and the log. Emergency lighting you never test is a battery you hope works. Test monthly, do the full-duration test annually, keep dates and results. Batteries typically need replacing every few years; the date is on the unit.
Emergency lighting is one part of the escape picture. Doors, alarms and the means of escape work together. See smoke and heat alarms, fire door closers and strips, key safes and the first-time landlord kit. If a power cut leaves tenants in a stairwell, a torch is a stopgap, not a plan; for personal kit, see rechargeable torches.
What salesmen push that doesn’t matter. Lumens figures with no standard behind them, colour temperature, and a fitting that looks smart. A battery light that glows in a hall for a minute is not emergency lighting.
Questions I get asked
Does my HMO need emergency lighting? Not automatically. It depends on the size and layout of the building, the length and complexity of the escape route, and your licence conditions. The fire risk assessment will say, and a council licence can require it where the assessment does not.
What is the difference between maintained and non-maintained? A maintained light is on all the time and stays on when the mains fails; a non-maintained light only comes on when the mains fails. Non-maintained suits most shared houses.
How often should emergency lighting be tested? BS 5266-8 describes a short monthly test and a full-duration test annually, with the results logged. Self-testing fittings automate the routine, but you still need to read the indicators.
Can I fit emergency lighting myself? The fittings are simple, but the supply is not. They need a permanent live and the right circuit, so use a competent electrician and ask for a certificate for the work.
Escape routes are one of the first things I look at in a shared house or a conversion, and a missing or dead emergency light is a quick fix before it becomes a licence or insurance problem. A buy to let survey will note them, and getting in touch is the way to arrange one. For the rest of the kit, there are more field-kit guides.
Small print. This guide is general information, not a fire risk assessment or an emergency lighting design for your property. Fire safety duties depend on the building and how it is used, so take advice from a competent fire risk assessor before acting. Prices are indicative, move constantly and are checked at the time of writing; the linked page always shows the current price. As an Amazon Associate I earn from qualifying purchases.